Corner Locked Steel Raised Access Flooring OA 500 For Underfloor Cabling System

Brand Name : HT
Model Number : HT-1000
Certification : ISO/CE/SGS/PSB
Place of Origin : Changzhou, China
MOQ : Negotiable
Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability : 60,000Sqm Per Month
Delivery Time : 7 Working Days within 6 Containers
Packaging Details : Panels with Pallets, Accessories with Cartons
Model NO : FS662-FS1500
Material : Steel, Cement
Size : 500*500mm
Usage : General Office
Customized : Yes
Type : Corner Lock System
Standard : CIACA/EN/MOB
HS Code : 7308900000
Contact Now

Corner Locked Steel Raised Access Flooring OA 500 For Underfloor Cabling System​


Description:

The 'OA 500 Steel Raised Floor For Underfloor Cabling System Corner Lock System' system forms a rigid membrane by safely locking the panels in position, from above - by corner fixing screws. This locking system creates a stringerless raised floor that is capable of withstanding normal static and dynamic loads experienced in the majority of general office environments.


Application

5A class office building, intelligent office environment, meeting room, commercial and industrial bureau, government, places that have requirements of dust-proof and water-proof, fields with aerial requirements.


Characteristics

  • Designed specially for office building
  • Excellent rolling load & ultimate load performance
  • Completely noncombustible
  • Black electrodeposition cathodic epoxy paint finish for life time protection
  • Class A flame spread and smoke development rating

Accessories

More designs and colors for your options and projects, pls kindly contact our sales


Technical Paramter

TypeSizeUniform loadConcentrated loadRolling loadImpact loadUltimate load
0.100''/2.5mm DEFLECTION10PASS10KPAAASS
FS662500*500*28mm

14.71

KN/㎡

2.94KN300KG2.45KN2.00KN100LB/45KG8.85KN
FS800500*500*28mm

17.78

KN/㎡

3.56KN363KG2.94KN2.45KN100LB/45KG11.25KN
FS1000500*500*28mm

22.22

KN/㎡

4.45KN454kG3.56KN2.67KN150LB/68KG14.50KN
FS1250500*500*28mm

27.78

KN/㎡

5.56KN567KG4.45KN3.56KN150LB/68KG18.36KN
FS1500500*500*28mm

33.34

KN/㎡

6.68KN680KG5.56KN4.45KN175LB/68KG22.17KN

Benefits of Raised Floor

Integrated raised floor for telecommunication, power and air distribution offer several economic and environmental benefits.

  • Ease of reconfiguration, and easy access

The integrated raised floor system is engineered to permit fast, easy installation and quick wire and cable changes, enhancing the ability to reconfigure the offices without disrupting power, voice and data services, as well as the air distribution system.Variable Air Volume (VAV) Terminals can be easily added, removed or rearranged to respond to changes in occupancy or heating and cooling loads. Even in workplaces with very low churn rates, constantly evolving technologies in the communications and networking sectors may demand occasional updating of the cabling and wiring systems. These updates are quite simple with raised floor.

  • Energy savings

The use of an raised floor plenum for conditional air distribution can significantly reduce energy use in many possible ways, such as a reduced fan power requirement. The underfloor supply plenum with the large cross-sectional flow areas can supply air with very low overall pressure drops.

It also provides higher chiller efficiency. Underfloor systems can use warmer supply air, which permits a warmer cooling coil and warmer evaporator temperature in dry climates.

In mild climates, the use of warmer supply air significantly expands the opportunity to use free cooling or the direct use of outside air, without operating a chiller.

Also, since the airflow is from floor to ceiling, most of the heat generated from ceiling-mounted lights is removed before it can enter the occupied zone. The cooling load is therefore reduced, allowing warmer air to condition the space.

In turn, the concrete slab becomes an active thermal mass, thus reducing temperature swings and peak coolingm requirements, and permitting the realisation of benefits such as night precooling in underfloor air applications.

  • Capital (First Cost) savings

In new construction, the use of an raised floor for service distribution can considerably reduce the overall building height, since floor plenums are usually shallower than ceiling plenums. raised floor can lower structural costs by allowing architects to reduce the floor-to-floor (slab-to-slab) height.

In addition, the adjustable raised floor pedestals accommodate imperfections in the floor slab, allowing the floor to be laser-levelled. The construction schedule can also be tightened by eliminating the need for slab screeding.

  • Occupant health and comfort

Reportedly, the most common complaints among employees are thermal discomfort and indoor air quality. With floor-mounted diffusers or workstation-mounted solutions such as task air modules or personal environment systems, the air is distributed directly to the workstation.

The occupants have the ability to control both the volume and the direction of the incoming air, and the fan units can be turned off to accommodate reduced cooling requirements.

As a result, personal comfort complaints are virtually eliminated. Case studies also show reduced absenteeism levels, since the system improves the indoor environmental conditions in other ways as well.

These include air quality improvements due to better pollutant removal – the upward flow of the supply air draws the pollutants upward rather than letting them swirl around with the room air.


All these benefits could result, under certain conditions, in substantial overall cost savings. However, raised floor are often eliminated from the building planning out of concern for higher first costs, but capital costs for the integrated system are comparable to traditional construction, while many other benefits detailed earlier result in significantly reduced life-cycle costs that are hard to overlook.

Raised floor are widely used throughout many countries and are a standard in Europe, UK, USA, Japan and the Middle East.

While raised floor are most often used in new buildings, they have started to be utilised in renovation projects as well, with a greater role in structures being totally rehabilitated.

In cases where the building interior is completely stripped, raised floor become an excellent renovation tool, construction goes much faster, and pre-engineering work required to locate supply duct-work does not have to be performed.

Developers have also begun to embrace the idea that the flexibility of integrated raised floor systems, can and often do, cut move-in times and make generically designed office space suitable for a wide range of potential tenants.


GET YOUR FREE SAMPLE NOW!!!



Product Tags:

raised floor systems

      

office raised floor

      
China Customized Inflatable Bumper Ball Game Bubble Adult Grass CE supplier

Corner Locked Steel Raised Access Flooring OA 500 For Underfloor Cabling System Images

Inquiry Cart 0
Send your message to this supplier
 
From:
Enter your email please.
To: CHANGZHOU HT RAISED FLOOR CO.,LTD
Subject:
Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0